Description
Sika’s Sikafloor-050 Ramp and Patch is a fast-setting mortar for ramping and patching concrete internally and externally. Its rapid early strength gain — around 30MPa after just one day, rising to about 40MPa at 28 days — is what makes it suitable for jobs like forming a ramp edge or patching a damaged section of slab where the area needs to be back in service quickly, rather than waiting out a slower-curing repair mortar.
At 1 gram per litre VOC, it’s also a very low-emission product, relevant on occupied sites or where indoor air quality standards matter, and it carries a Green Star VOC-SCQMD Rule 1168 test certificate for projects that need that documented. A short 15 minute pot life keeps the mortar workable and easy to shape by trowel, but does mean mixing in small batches to match the pace of placement.
Technical Specifications
| Product type | Fast-setting ramping and patching mortar |
|---|---|
| Appearance | Grey powder |
| VOC content | 1 gram per litre (very low) |
| Compressive strength — 1 day | Approx. 30MPa |
| Compressive strength — 28 days | Approx. 40MPa |
| Packaging | 20kg bag, 48 bags per pallet |
| Mixing water | 4 to 4.2 litres per 20kg bag |
| Layer thickness | 1 to 50mm |
| Pot life | 15 minutes at 23°C |
| Application temperature | 10°C to 35°C ambient air |
| Certification | Green Star VOC-SCQMD Rule 1168 test certificate |
| Shelf life | Unopened bags up to 9 months, cool and dry conditions |
Where to Use
- Ramping and patching internal and external concrete floors
- Fast-track repairs needing rapid early strength
- Metal substrates and concrete floors that are fully cured and structurally sound
How to Apply
- Prepare the substrate — concrete floors must be fully cured, structurally sound, clean and dry, free of surface contaminants; not recommended over slabs with efflorescence or high moisture.
- Mix — combine 4.1 to 4.3 litres of clean, cool water with the 20kg bag.
- Place within the pot life — apply within 15 minutes of mixing.
- Trowel to shape — pack and shape with a trowel to form the required ramp or patch profile.
- Allow to cure — protect from drying too fast; let all coated areas dry evenly.
Important Notes
- Not recommended as a final trafficable wearing surface — cover with an appropriate topping or floor covering.
- Do not mix or apply over a concrete substrate with efflorescence or high moisture content.
- Mix only as much as can be placed within the 15 minute pot life.
- Ambient air temperature should be within 10°C to 35°C during application.