Description
Ultraset 3 in 1 from Bostik does three jobs in one trowelled layer: it bonds the timber, controls moisture vapour from the slab and reduces impact noise. Bostik‘s Thickness Control spacer technology, the black granules in the beige adhesive, keeps the bed at a consistent thickness between board and slab. Bostik says its sound control typically outperforms a 3mm rubber underlay, and the floor takes light traffic straight away.
It is made in Australia from Bostik’s AXIOS Tri-Linking polymer with Blockade anti-microbial protection and zero VOC content. It bonds hardwood, solid strip softwood, engineered flooring, parquet, cork and bamboo with no limit on board size, bridges cracks up to 3mm and suits radiant (underfloor) heating.
Technical Specifications
| Manufacturer | Bostik Australia |
|---|---|
| Composition | 1-part AXIOS Tri-Linking polymer, moisture cure |
| Colour | Beige with black granules |
| Packaging | 26kg (15.3L) pail (Bostik code 30615274) |
| Density | 1.71 kg/L |
| Application temperature | 10°C to 38°C |
| Open / working time | 60 minutes (see open time chart in TDS) |
| Walk on time | Light traffic immediately; normal foot traffic after 12 to 24 hours |
| Elongation | Over 100% |
| Crack bridging | Up to 3mm |
| VOC content | 0 g/L (as calculated per SCAQMD Rule 1168) |
| Coverage | About 12 to 13 m² per 26kg pail, 6 x 6mm V-notch trowel |
| Shelf life | 12 months, off the ground in a cool, dry place |
Sound Reduction Results (Bostik, in situ)
| Slab | Flooring | Ceiling | L’nT,w |
|---|---|---|---|
| 200mm concrete | 14mm engineered | 13mm suspended plasterboard | 42 |
| 160mm concrete | 15mm engineered | 13mm acoustic plasterboard, 250mm void, 75mm glass wool | 49 |
| 250mm concrete | 14.5mm engineered | No suspended ceiling | 53 |
How to Apply
- Prepare: the subfloor must be clean, dry, sound and flat to 3mm over 3m. Lightly sand yellow tongue particleboard and remove old adhesive and coatings.
- Mix any milky liquid on top back in with a gauging trowel.
- Full trowel with a 6mm V-notch trowel for 100% coverage of the slab.
- Lay and check: set boards straight away and lift some periodically to confirm 100% transfer. Re-trowel at 90° if the adhesive skins.
- Hold down solid strip boards with weights, or nail per ATFA guidance.
Important Notes
- Below-grade installs are limited to engineered flooring, and on or below grade slabs need a vapour barrier properly installed below the slab.
- Do not use over negative hydrostatic head, sealers or curing compounds, perimeter bonded flooring, or wet, dusty, glassy smooth or friable surfaces. Do not lay solid timber over vinyl.
- Needs atmospheric moisture to cure: not for totally confined or air-free spaces. Recommended slab temperature 10°C to 35°C.
- Keep water and alcohol-based cleaners off until fully cured. Sand only after full cure (minimum 24 hours; industry practice suggests 3 to 14 days).
- Bostik’s SDS lists it as a skin sensitiser (H317, Warning) that releases small amounts of methanol while curing. Wear gloves and eye protection. Not regulated as Dangerous Goods.