Description
Sika SikaSil 702 Premium Pure Silicon Sealant
– Available as 300ml Cartridge
Sikasil®-702 is a premium grade one-component neutral curing silicone sealant with
good adhesion, elasticity and weatherability for all trade and home internal and
external sealing applications. Sikasil®-702 is easy to apply does not contain any
fillers and cures through the absorption of atmospheric moistureto form a tough
flexible waterproof seal.
USES
Sikasil®-702 All Purpose is suitable for:
- Kitchens & Bathrooms
- Basins
- Baths
- Toilets
- Shower screens & tiled wet areas
- Benchtops & Around splashbacks
- Roofs & Gutters including polycarbonate
- Around plumbing fixtures and penetrations
- Sealing windows & door frames
- General interior & exterior sealing
– Not suitable for natural stone, some porous materials and copper
FEATURES
- No fillers
- Neutral cure
- Non-corrosive
- Interior & exterior use
- Mould resistant
- Good adhesion to most common building materials including: glass,
ceramic, painted surfaces, concrete, wood, polycarbonate, most metal & most
plastic - High movement capability ± 25%
- Very easy to apply & fast curing
- Excellent temperature resistance (-40°C to +150°C)
PRODUCT INFORMATION
Composition
- Neutral cure silicone
Packaging
- 300ml Cartridges (12 Cartridges per box)
Shelf Life
- 12 months from the date of production
Storage Conditions
- The product must be stored in original, unopened and undamaged sealed
packaging in dry conditions at
temperatures between +5°C and +25°C. - Refer to the current Safety Data Sheet for information on safe handling
and storage. - Always refer to packaging.
Appearance and Colour
- 300ml Cartridge – White, Off White, Alabaster, Almond Ivory, Taupe,
Beige, Tile Grey, Mid Grey, Grey, Earth Grey, Bluestone, Pewter, Charcoal, Black &
Translucent
Density
- 1.01 kg/l approx.
TECHNICAL INFORMATION
Shore A Hardness
- ~28 after 28 Days
Service Temperature
- -40ºC to +150ºC
Movement Capability
- ± 25 % (ASTM C719)
Water Contact
- AS/NZS 4020:2018 – Water Potable Approved
Joint Design
For movement joints, the width must be at least 6 mm and should not exceed 45 mm.
For non-movement joints such as connection joints in interior areas, the joint width
can be less than 6 mm.
The joint dimensions must be designed to suit the movement capability of the
sealant. In all cases joints must be at least 6 mm deep, or a have a width to depth
ratio of 1 : 0.5 (for exceptions, see table below).
Typical joint dimensions for joints between concrete elements:
- 12 metre long joint – 6mm width – 4mm Depth
- 6 metre long joint – 9mm width – 5mm Depth
- 4 metre long joint – 12mm width – 6mm Depth
For more information about joint design and calculations refer to the Sika document
Design guideline: Dimensioning of construction joints or contact Sika Technical
Services.
APPLICATION INFORMATION
Sag Flow
- Nil Sag
Ambient Air Temperature
- +5 °C to +40 °C
Substrate Temperature
- +5 °C min. / +40 °C max. Minimum +3 °C above dew point temperature and
free from frost and ice
Backing Material
- Use closed cell polyethylene foam backing rod or backing tape
Curing Rate
- ~4.0 mm / 24 hours (+23 °C / 50 % r.h.)
SkinningTime
- ~10 min (+23 °C / 50 % r.h.)
IMPORTANT CONSIDERATIONS
- Sikasil®-702 cannot be overpainted.
- When applying sealant into a previously silicone sealed joint, ensure
all residue is removed from joint. - Do not use on natural stone.
- Do not use on bituminous substrates, natural rubber or any building
materials which might leach oils, plasticisers or solvents that could degrade the
sealant. - EPDM or other gaskets in direct contact must be tested for compatibility
prior to application. - Do not use on pre-stressed polyacrylate and polycarbonate as it may
cause environmental stress cracking (crazing). - Do not use on copper.
- Do not use Sikasil®-702 in areas which are exposed to strong oxidising
acids (e.g. nitric acid) and bases. - Do not use to seal joints in or around swimming pools for joints under
water pressure or permanent water immersion. - Do not use Sikasil®-702 in totally confined spaces as it requires
atmospheric moisture to cure. - Do not use for medical or pharmaceutical applications.
- Colour variations may occur due to the exposure in service to chemicals,
high temperatures and/or UV radiation (especially with white colour shade). This
effect is aesthetic and does not adversely influence the technical performance or
durability of the product.