Description
Roberts R6037 Synthetic Grass Carpet Adhesive
– 20 Litres
PRODUCT DESCRIPTION:
ROBERTS R6037 Synthetic Grass Carpet Adhesive is an all-weather solvent-based (flammable) adhesive specifically formulated for the outdoor installation of non-stretch open weave polypropylene-backed synthetic grass carpets.
It is not recommended for urethane and E.V.A.-backed carpets.
ROBERTS R6037 Synthetic Grass Carpet Adhesive develops high strength quickly and, when cured, will withstand unfavourable weather conditions.
SUITABILITY:
- ROBERTS R6037 Synthetic Grass Carpet Adhesive will bond securely to cured concrete, asphalt, exterior grade wood and other clean paved surfaces and is ideal for use around swimming pools, balconies, outdoor recreational areas, and other applications which are subject to moisture after fixing.
SURFACE PREPARATION:
- Follow all current Australian Standards, Including, Australian Standard 2455.2.2019 “Textile Floor Coverings Installation Practice” & “Floor Coverings 1884-2021 Resilient Sheet & Tiles – Laying & Maintenance Practices”.
- All surfaces to be bonded shall be absorbent, dry, smooth, sound, and clean.
- Subfloors must also be free of wax, grease, paint, previously used adhesive, polish, PVC-based membranes, curing compounds, hydrostatic pressure and any other impurities that may affect adhesion.
- The minimum subfloor temperature before commencing surface preparation and adhesive application is 10°C.
- Test all concrete substrate flooring for moisture content according to the current Australian Standards before priming or installing any floor coverings.
- Where temperatures are less than 5°C or higher than 35°C, please contact RLA Technical department for further details.
APPLICATION:
- Spread adhesive with the recommended V-notched trowel.
- Apply adhesive using a ‘V’ notched trowel spreader.
- Dimensions of notching should be such as to provide a minimum 75% coverage of adhesive to the back of the flooring.
- As most synthetic grass and fibre bonded carpets have a highly textured backing, a deep 3.2mm x 3.2mm notching is recommended.
- Allow adhesive to develop some initial tack-approximately 5-10 minutes at 20°C before lowering floor covering into the wet film of adhesive and rolling to ensure adhesive transfer has occurred onto the backing of the floor covering.
- Tack-up time will depend upon atmospheric conditions and substrate absorbency.
- Complete installation according to manufacturer’s instructions, ensuring the installation is rolled in both directions with the recommended roller weight before the adhesive setting.
- Do not allow heavy traffic for 24 hours.
- Do not apply adhesive in the rain or if rain is expected during or shortly after laying.
- Apply in a well-ventilated area.
SPREAD RATE:
- 2.4mm x 2.4mm V2 Trowel – 3m2/L
- 3.2mm x 3.2mm V3 – 2m2/L
- 3.2mm x 3.2mm “U” – 1.6m2/L
Spread rates may vary depending on the condition and substrate absorbency.
SHELF LIFE/STORAGE:
- 12 months when stored in original unopened packaging
- Shall be stored in a dry area off the ground.
PACKAGING:
- 20 Litre Containers
CLEAN UP:
- Clean tools immediately after use with RLA approved
ROBERTS R900 Cleaner.
HIGHLY FLAMMABLE:
- Avoid contact with skin and eyes and avoid breathing vapour.
FIRE:
- In the case of FIRE, use foam to extinguish.
- Firefighters should wear full protective clothing and self-contained breathing apparatus.
NOTES AND PRECAUTIONS:
- Drying times can be extended when applied in cold ambient temperatures.
- Don’t allow the adhesive to skin over or dry out; the floorcovering being bonded is essential to be installed into the Wet film of adhesive.
- Don’t apply adhesive in direct sunlight.
SAFETY AND HANDLING:
KEEP away from HEAT/SPARKS/OPEN FLAMES and HOT SURFACES/NO SMOKING
- Keep the container tightly closed
- Avoid contact with skin and eyes and avoid breathing vapour.
- Ground/bond container and receiving equipment Use explosion-proof electrical/ventilation/lighting equipment.
- Use only non-sparking tools.
- Take precautionary measures against static discharges
- Avoid breathing vapours.
- Use only outdoors or in well-ventilated areas.
- Wear protective gloves and eye and face protection.
- Wash thoroughly after handling.
- People sensitive to odours and chemicals should avoid the work area.
- During the installation process, adequate ventilation of the work area should be maintained.
- Do not handle until Safety Directions have been read and understood.
- Safety Data Sheet is available upon request.
FIRST AID:
- If poisoning occurs, contact a doctor or Poisons Information Centre.
- For advice or if you feel unwell, contact a Poisons Information Centre: Australia ph. 131126,
New Zealand ph. 0800 764 766 or a doctor at once. - If swallowed, DO NOT induce vomiting. Give a glass of water.
- IF SWALLOWED, immediately call the Poisons Information Centre or a doctor.
- IF ON SKIN Remove immediately all contaminated clothing and wash skin with soap and water.
- If skin irritation occurs, get medical advice/attention.
- IF IN EYES Rinse carefully with water for several minutes.
- If eye irritation persists, get medical advice/attention.
- Refer to The Safety Data Sheet available with the Multifors product data.